Automatic Addressable Fire Detection & Alarm System
Automatic addressable Fire Detection system consists the wide range of detectors
and panels . The detectors senses cause of fire and then gives the signal through
the alarm system.
Analogue Addressable Fire Alarm systems Analogue Addressable
Fire Alarm Systems differ from conventional systems in a number of ways and certainly
add more flexibility, intelligence, speed of identification and scope of control.
For this reason Analogue Addressable Fire Alarm Systems are the natural choice for
larger premises and more complex system requirements. In an analogue addressable
system detectors are wired in a loop around the building with each detector having
its own unique 'address'. The system may contain one or more loops depending upon
the size of the system and design requirements. The Fire Control Panel 'communicates'
with each detector individually and receives a status report e.g. Healthy, In Alarm
or In Fault etc. As each detector has an individual 'address' the fire alarm control
panel is able to display/indicate the precise location of the device in question,
which obviously helps speed the location of an incident and for this reason 'zoning'
of the system is not necessary, although it may be done for convenience.
Addressable detectors are, in themselves, 'intelligent' devices which are capable
of reporting far more than just fire or fault conditions, for example most detectors
are able to signal if contamination within the device (dust etc) reaches a pre-set
level enabling maintenance to take place prior to problems being experienced. Addressable
detectors are also able to provide pre-alarm warnings when smoke/heat levels, reach
a pre-set level enabling investigation of the fire to take place prior to a full
evacuation alarm and Fire Brigade signaling taking place.
Sounders may either be conventionally wired or by using addressable sounders, wired
upon the "loop" thereby making considerable savings in terms of cable and labour.
Area of Application: Commercial Buildings, Residential
Apartments, Hospitals & Hotels. Etc.
Approvals: NBC,
TAC, IS, FM, NFPA, and Local Fire Authorities
Detectors Non Addressable type & Addressable type
|
|
VESDA aspirating System. |
|
Smoke Detectors ( Ionization/Photo/Optical). |
|
Heat Detectors (Fixed Temp/Rate of rise cum fixed temp.) |
Special Detectors: Detectors have two states, Normal
healthy and Alarm. The consequence of a fire, if not detected and guarded against
instantaneously, can be disastrous.
Area of Application: Commercial Buildings, Residential
Apartments, Hospitals & Hotels. Etc.
Approvals: NBC, TAC, IS, FM.NFPA, and Local Fire Authorities
|
|
Smoke & Heat Combined Detector |
|
Linear Heat sensing cable |
|
Laser Detector
|
|
Beam Detector |
|
UV-Detector
|
|
IR-Detector |
|